High-Temperature Specific Heat Capacity Tester
The GHC-II determines the specific heat capacity of solid materials at set temperatures by the method of mixtures, with computer acquisition of the specimen and calorimeter temperature changes. It covers room temperature to 1,400 °C for specific-heat-capacity testing of solid materials in research and teaching laboratories.
- Model
- GHC-II
- Category
- Specific Heat Capacity
Product Description
The GHC-II is a high-temperature specific heat capacity tester that applies the method of mixtures to solid materials. The system consists of a vertical tubular resistance furnace, a thermostat, a temperature controller, a high-precision thermometer, a calorimeter and a computer test system.
In a test the specimen is heated in the tubular furnace to the test temperature and then dropped into the calorimeter. The computer measurement system records the temperature changes of the specimen and the calorimeter over the whole test, from which the specific heat capacity of the material is obtained. Specimens that oxidize readily at high temperature need the vacuum system.
The furnace runs from room temperature to 1,400 °C under programmed PID control, with ±0.3 K per 30 min temperature-control accuracy depending on the setting and 0.01 K minimum temperature resolution. The calorimeter is evacuated below 2 × 10⁻³ Pa and the furnace below 5 Pa, the furnace level chosen by the user for the specimen.
Specimens are 11 mm in diameter and 30 mm high; powders are tested in a standard specimen container. The test principle follows GJB 330A-2000 and GJB 1715-93. The legacy test software runs on Windows XP with a Chinese interface.
Ordering information: Specify the maximum test temperature, the heating element and the atmosphere or vacuum it requires, specimen form and size, and the current software platform when requesting a quotation.
Technical Specifications
| Parameter | Specification |
|---|---|
| Measured property | Specific heat capacity of solid materials |
| Method | Method of mixtures |
| Temperature range | Room temperature–1,400 °C |
| Temperature-control accuracy | ±0.3 K per 30 min (setting-dependent) |
| Minimum temperature resolution | 0.01 K |
| Temperature control | PID, programmed |
| Data acquisition | Computer acquisition over the full test |
| Calorimeter vacuum | Below 2 × 10⁻³ Pa |
| Furnace vacuum | Below 5 Pa (set by the user for the specimen) |
| Specimen size | 11 mm diameter × 30 mm high |
| Powder specimens | Standard specimen container |
| Software | Legacy Windows XP software with a Chinese interface |
| Referenced standards | GJB 330A-2000; GJB 1715-93 |